Interpreting the Inspection Results
Each item or area inspected will be marked with a finding, which represents the inspection result for that item. The following descriptions represent an explanation for each of the inspection findings. Inspected - Appears Functional = The item, component, or unit was visually observed, and if no other comments were made, then the item appeared to be functioning as intended, allowing for normal wear and tear.
|
Scott Home Inspection, LLC |
| Date: 3/1/2007 | Time: 8:30 AM | Report ID: Sample-13 |
| Property: 123 Main Street Loveland, CO 80539 |
Customer: John & Mary Smith |
Real Estate Professional: Janet Evans County Real Estate |
| 1.2 | SKYLIGHTS, CHIMNEYS AND ROOF PENETRATIONS | |
| Repair or Replace | ||
|
There are old, un-used brackets mounted on the roof, that appear to be from an old antenna or dish. While the brackets seem well secured, there is a concern for developing roof leaks at the point of penetration. Recommend removal of these brackets, and properly sealing penetration holes, to prevent any future roof leaking at this point. |
||
| 2.0 | WALL CLADDING FLASHING AND TRIM | |
| Repair or Replace | ||
|
The Cement board at the garage right side (facing front) is loose and damaged. Deterioration can eventually occur if not corrected. A qualified person should repair or replace as needed. |
||
| 2.1 | DOORS (Exterior) | |
| Repair or Replace | ||
|
The main entry door needs weather-stripping repaired or replaced. This can cause some heat loss in winter and loss of cool air in summer if not corrected. A qualified person should repair or replace as needed. |
||
| 2.4 | VEGETATION, GRADING, DRAINAGE, DRIVEWAYS, PATIO FLOOR, WALKWAYS AND RETAINING WALLS (With respect to their effect on the condition of the building) | |
| Repair or Replace | ||
|
The Concrete patio at the front of home has settlement cracks and is uneven, and can be a tripping hazard. A fall or injury can occur if not corrected and further deterioration can occur if not repaired. A qualified contractor should inspect and repair as needed. |
||
| 4.4 | COUNTERS AND A REPRESENTATIVE NUMBER OF CABINETS | |
| Repair or Replace | ||
|
Drawer track is damaged (right of dishwasher). This is a cosmetic issue for your information. Recommend repair or replace as necessary. |
||
| 6.1 | NORMAL OPERATING CONTROLS | |
| Repair or Replace | ||
|
The thermostat is fully functional, but is loose on wall. I recommend repair or replace as needed. |
||
| 7.0 | SERVICE ENTRANCE CONDUCTORS | |
| Repair or Replace | ||
|
The electrical service conductors are in contact with trees, between the main service drop at the road, and the service entrance connection at the house. This can cause fraying of wires and possible damage to wires. It is recommended that trees and vegetation be trimmed around service entrance conductors, to prevent damage. |
||
| 7.1 | SERVICE AND GROUNDING EQUIPMENT, MAIN OVERCURRENT DEVICE, MAIN AND DISTRIBUTION PANELS | |
| Repair or Replace | ||
|
The main panel box is located at the outside service pole. The panel door is damaged. This is a safety issue that needs to be corrected and could result in water entry and future corrosion. A qualified licensed electrician should correct as needed. |
||
| 7.3 | CONNECTED DEVICES AND FIXTURES (Observed from a representative number operation of ceiling fans, lighting fixtures, switches and receptacles located inside the house, garage, and on the dwelling's exterior walls) | |
| Repair or Replace | ||
|
(1) Exposed wiring at the light fixture in the garage. This is a safety issue that needs to be corrected. A qualified licensed electrician should perform repairs that involve wiring. |
||
| 8.1 | PLUMBING WATER SUPPLY AND DISTRIBUTION SYSTEMS AND FIXTURES | |
| Repair or Replace | ||
|
(1) The area behind the faucet is missing caulking/sealant at the kitchen sink. This area should be caulked to prevent water penetration. Water leaking under home can cause problems such as mold, erosion or deterioration. A qualified person should repair as necessary. |
||
| 9.0 | FOUNDATIONS, BASEMENTS AND CRAWLSPACES (Report signs of abnormal or harmful water penetration into the building or signs of abnormal or harmful condensation on building components.) | |
| Repair or Replace | ||
|
The Foundation wall at the left side (facing front) and right corner (facing rear) has exposed exterior insulation. The insulation should not be exposed, to prevent damage & deterioration. The foundation grading in this area should be improved. |
||
| 9.1 | WALLS (Structural) | |
| Repair or Replace | ||
|
The sheetrock on the wall has a hairline, settlement crack at the Dining Room main entryway. This damage is most likely cosmetic, caused by minor settling of the home. A qualified structural engineer should inspect and repair as needed. |
||
| 10.1 | INSULATION UNDER FLOOR SYSTEM | |
| Repair or Replace | ||
|
(1) The insulation is loose/fallen in the crawlspace under the living room. Heat loss can occur more on this home than one that is properly insulated. A qualified person should repair or replace as needed. |
||
| 10.4 | VENTING SYSTEMS (Kitchens, baths and laundry) | |
| Repair or Replace | ||
|
The dryer vent piping is no longer used at this location. Any un-used vents should be properly terminated and blocked off, to prevent moisture or pest entry into the house. I recommend repair as needed. |
||
Prepared Using HomeGauge http://www.homegauge.com SHGI (c) 2000-2004 : Licensed To Scott Home Inspection, LLC
Scott Home Inspection, LLC |
| Date: 3/1/2007 | Time: 8:30 AM | Report ID: Sample-13 |
| Property: 123 Main Street Loveland, CO 80539 |
Customer: John & Mary Smith |
Real Estate Professional: Janet Evans County Real Estate |
| 1.3 | ROOF DRAINAGE SYSTEMS | |
| Maintenance Issues | ||
|
The gutter screens are loose at the left corner (facing rear) rear of home. If gutter screens are not properly in place, leaves can contribute to a clog which can cause deterioration of fascia, soffit or roof edge. It can also cause gutters to pull loose and lead to possible water intrusion. Recommend repair as desired. |
||
| 4.2 | FLOORS | |
| Maintenance Issues | ||
|
I recommend silicone caulk along floor and tub at hall bath. There is some visible deterioration of the existing caulking. Leaking could occur causing damage to sub-flooring and structure. No indication of damage exists today. However the deteriorated caulking should be repaired. |
||
| 6.6 | GAS/LP FIRELOGS AND FIREPLACES | |
| Maintenance Issues | ||
|
There is a gas shut-off valve located where indicated, for the gas appliance shown. This item is noted as a courtesy comment only, for future reference in the event gas shut off is required. |
||
| 8.0 | PLUMBING DRAIN, WASTE AND VENT SYSTEMS | |
| Maintenance Issues | ||
|
There is a plumbing clean-out located outside, which allows access to the waste drain, in the event of back-up or clogs. This item is noted for reference only, and for future maintenance consideration. |
||
| 8.3 | MAIN WATER SHUT-OFF DEVICE (Describe location) | |
| Maintenance Issues | ||
|
The main shut off is the red knob located in the basement on the rear wall. This is for your information. |
||
| 8.4 | FUEL STORAGE AND DISTRIBUTION SYSTEMS (Interior fuel storage, piping, venting, supports, leaks) | |
| Maintenance Issues | ||
|
The propane tank inlet line runs into the ground, toward the house, but is exposed at the surface. Care should be taken when working around or near this area, to prevent any damage to the propane gas line. |
||
| 10.5 | VENTILATION FANS AND THERMOSTATIC CONTROLS (ATTIC) | |
| Maintenance Issues | ||
|
Thermostatically controlled vent fan in the attic is functioning. Location of thermostat control is noted on report detail photograph, for reference. This is for your information. Adjustments are possible, and the homeowner should become familiar with the method of setting. |
||
Prepared Using HomeGauge http://www.homegauge.com SHGI (c) 2000-2004 : Licensed To Scott Home Inspection, LLC
Scott Home Inspection, LLC |
| Date: 3/1/2007 | Time: 8:30 AM | Report ID: Sample-13 |
| Property: 123 Main Street Loveland, CO 80539 |
Customer: John & Mary Smith |
Real Estate Professional: Janet Evans County Real Estate |
Inspection Areas
Exterior - Grounds
Foundation - Basement - Crawlspace
Roofing - Attic
Plumbing System
Electrical System
Heating System
Air Conditioning System
Interior
Built-in Kitchen Appliances
Garage
Other Areas/Systems
![]() |
| Roof Covering: 3-Tab fiberglass | Viewed roof covering from: Walked roof | Sky Light(s): One |
| Chimney (exterior): Metal Flue Pipe |
| 1.0 | ROOF COVERINGS Inspected | |
This is a general picture of the roof material and type.
|
| 1.1 | FLASHINGS Inspected |
| 1.2 | SKYLIGHTS, CHIMNEYS AND ROOF PENETRATIONS Repair or Replace | |
There are old, un-used brackets mounted on the roof, that appear to be from an old antenna or dish. While the brackets seem well secured, there is a concern for developing roof leaks at the point of penetration. Recommend removal of these brackets, and properly sealing penetration holes, to prevent any future roof leaking at this point.
|
| 1.3 | ROOF DRAINAGE SYSTEMS Maintenance Issues | ||
The gutter screens are loose at the left corner (facing rear) rear of home. If gutter screens are not properly in place, leaves can contribute to a clog which can cause deterioration of fascia, soffit or roof edge. It can also cause gutters to pull loose and lead to possible water intrusion. Recommend repair as desired.
|
![]() | ![]() |
![]() | ![]() |
| Siding Style: Lap | Siding Material: Cement-Fiber | Exterior Entry Doors: Steel |
| Appurtenance: Covered porch Sidewalk Deck Patio | Driveway: Gravel |
| 2.0 | WALL CLADDING FLASHING AND TRIM Repair or Replace | |
The Cement board at the garage right side (facing front) is loose and damaged. Deterioration can eventually occur if not corrected. A qualified person should repair or replace as needed.
|
| 2.1 | DOORS (Exterior) Repair or Replace | |
The main entry door needs weather-stripping repaired or replaced. This can cause some heat loss in winter and loss of cool air in summer if not corrected. A qualified person should repair or replace as needed.
|
| 2.2 | WINDOWS Inspected |
| 2.3 | DECKS, BALCONIES, STOOPS, STEPS, AREAWAYS, PORCHES, PATIO/ COVER AND APPLICABLE RAILINGS Inspected |
| 2.4 | VEGETATION, GRADING, DRAINAGE, DRIVEWAYS, PATIO FLOOR, WALKWAYS AND RETAINING WALLS (With respect to their effect on the condition of the building) Repair or Replace | |
The Concrete patio at the front of home has settlement cracks and is uneven, and can be a tripping hazard. A fall or injury can occur if not corrected and further deterioration can occur if not repaired. A qualified contractor should inspect and repair as needed.
|
| 2.5 | EAVES, SOFFITS AND FASCIAS Inspected |
![]() |
| Garage Door Type: Two automatic | Garage Door Material: Insulated | Auto-opener Manufacturer: GENIE 1/3 HORSEPOWER |
| 3.0 | GARAGE CEILINGS Inspected |
| 3.1 | GARAGE WALLS (INCLUDING FIREWALL SEPARATION) Inspected |
| 3.2 | GARAGE FLOOR Inspected |
| 3.3 | GARAGE DOOR (S) Inspected |
| 3.4 | GARAGE DOOR OPERATORS (Report whether or not doors will reverse when met with resistance) Inspected | ||
Both Garage Doors will reverse when met with resistance.
|
![]() | ![]() |
![]() | ![]() |
| Ceiling Materials: Sheetrock | Wall Material: Sheetrock | Floor Covering(s): Carpet Wood |
| Interior Doors: Hollow core | Window Types: Double-hung | Window Manufacturer: CARADCO |
| Cabinetry: Wood Laminate | Countertop: Granite |
| 4.0 | CEILINGS Inspected |
| 4.1 | WALLS Inspected |
| 4.2 | FLOORS Maintenance Issues | |
I recommend silicone caulk along floor and tub at hall bath. There is some visible deterioration of the existing caulking. Leaking could occur causing damage to sub-flooring and structure. No indication of damage exists today. However the deteriorated caulking should be repaired.
|
| 4.3 | STEPS, STAIRWAYS, BALCONIES AND RAILINGS Inspected |
| 4.4 | COUNTERS AND A REPRESENTATIVE NUMBER OF CABINETS Repair or Replace | |
Drawer track is damaged (right of dishwasher). This is a cosmetic issue for your information. Recommend repair or replace as necessary.
|
| 4.5 | DOORS (REPRESENTATIVE NUMBER) Inspected |
| 4.6 | WINDOWS (REPRESENTATIVE NUMBER) Inspected |
![]() | ![]() |
| Dishwasher Brand: GENERAL ELECTRIC | Disposer Brand: IN SINK ERATOR | Exhaust/Range hood: GENERAL ELECTRIC |
| Range/Oven: GENERAL ELECTRIC | Built in Microwave: GENERAL ELECTRIC |
| 5.0 | DISHWASHER Inspected |
| 5.1 | RANGES/OVENS/COOKTOPS Inspected |
| 5.2 | RANGE HOOD Inspected |
| 5.3 | FOOD WASTE DISPOSER Inspected |
| 5.4 | MICROWAVE COOKING EQUIPMENT Inspected |
![]() | ![]() |
| Heat Type: Forced Air | Energy Source: Propane | Number of Heat Systems (excluding wood): Two |
| Heat System Brand: RHEEM Serial # : Criterion II | Ductwork: and Non-insulated Partially insulated | Filter Type: Disposable |
| Filter Size: 16x20 | Types of Fireplaces: Propane gas logs vented | Operable Fireplaces: One |
| 6.0 | HEATING EQUIPMENT Inspected |
| 6.1 | NORMAL OPERATING CONTROLS Repair or Replace | |
The thermostat is fully functional, but is loose on wall. I recommend repair or replace as needed.
|
| 6.2 | AUTOMATIC SAFETY CONTROLS Inspected |
| 6.3 | DISTRIBUTION SYSTEMS (including fans, pumps, ducts and piping, with supports, insulation, air filters, registers, radiators, fan coil units and convectors) Inspected |
| 6.4 | PRESENCE OF INSTALLED HEAT SOURCE IN EACH ROOM Inspected |
| 6.5 | CHIMNEYS, FLUES AND VENTS (for fireplaces, gas water heaters or heat systems) Inspected |
| 6.6 | GAS/LP FIRELOGS AND FIREPLACES Maintenance Issues | |
There is a gas shut-off valve located where indicated, for the gas appliance shown. This item is noted as a courtesy comment only, for future reference in the event gas shut off is required.
|
| Electrical Service Conductors: Overhead service 220 volts | Panel capacity: 100 AMP | Panel Type: Circuit breakers |
| Electric Panel Manufacturer: GENERAL ELECTRIC | Branch wire 15 and 20 AMP: Copper | Wiring Methods: Romex |
| 7.0 | SERVICE ENTRANCE CONDUCTORS Repair or Replace | |||
The electrical service conductors are in contact with trees, between the main service drop at the road, and the service entrance connection at the house. This can cause fraying of wires and possible damage to wires. It is recommended that trees and vegetation be trimmed around service entrance conductors, to prevent damage.
|
| 7.1 | SERVICE AND GROUNDING EQUIPMENT, MAIN OVERCURRENT DEVICE, MAIN AND DISTRIBUTION PANELS Repair or Replace | |
The main panel box is located at the outside service pole. The panel door is damaged. This is a safety issue that needs to be corrected and could result in water entry and future corrosion. A qualified licensed electrician should correct as needed.
|
| 7.2 | BRANCH CIRCUIT CONDUCTORS, OVERCURRENT DEVICES AND COMPATIBILITY OF THEIR AMPERAGE AND VOLTAGE Inspected |
| 7.3 | CONNECTED DEVICES AND FIXTURES (Observed from a representative number operation of ceiling fans, lighting fixtures, switches and receptacles located inside the house, garage, and on the dwelling's exterior walls) Repair or Replace | |
(1) Exposed wiring at the light fixture in the garage. This is a safety issue that needs to be corrected. A qualified licensed electrician should perform repairs that involve wiring.
| ||
(2) Exposed wiring at the electrical junction box at the master bedroom, under the bench seat, connecting power to the wall heater. This is a safety issue that needs to be corrected. A qualified licensed electrician should correct as needed.
|
| 7.4 | POLARITY AND GROUNDING OF RECEPTACLES WITHIN 6 FEET OF INTERIOR PLUMBING FIXTURES, AND ALL RECEPTACLES IN GARAGE, CARPORT, EXTERIOR WALLS OF INSPECTED STRUCTURE Inspected |
| 7.5 | OPERATION OF GFCI (GROUND FAULT CIRCUIT INTERRUPTERS) Inspected | |||
There is no GFCI outlet found in bath. This is a required safety component in a bathroom, and at least one device must be installed. I recommend a duplex GFCI outlet be installed by a licensed electrician.
|
| 7.6 | LOCATION OF MAIN AND DISTRIBUTION PANELS Inspected |
| 7.7 | SMOKE DETECTORS Inspected |
| Water Source: Public | Water Filters: None | Plumbing Water Supply (into home): Galvanized (old) |
| Plumbing Water Distribution (inside home): Copper | Washer Drain Size: 2" Diameter | Plumbing Waste: PVC |
| Water Heater Power Source: Propane (quick recovery) | Water Heater Capacity: (2) 40 Gallon | Manufacturer: RHEEM |
| 8.0 | PLUMBING DRAIN, WASTE AND VENT SYSTEMS Maintenance Issues | |
There is a plumbing clean-out located outside, which allows access to the waste drain, in the event of back-up or clogs. This item is noted for reference only, and for future maintenance consideration.
|
| 8.1 | PLUMBING WATER SUPPLY AND DISTRIBUTION SYSTEMS AND FIXTURES Repair or Replace | |
(1) The area behind the faucet is missing caulking/sealant at the kitchen sink. This area should be caulked to prevent water penetration. Water leaking under home can cause problems such as mold, erosion or deterioration. A qualified person should repair as necessary.
|
| 8.2 | HOT WATER SYSTEMS, CONTROLS, CHIMNEYS, FLUES AND VENTS Inspected | ||
The dual hot water heater installation is set-up properly in a parallel configuration.
|
| 8.3 | MAIN WATER SHUT-OFF DEVICE (Describe location) Maintenance Issues | ||
The main shut off is the red knob located in the basement on the rear wall. This is for your information.
|
| 8.4 | FUEL STORAGE AND DISTRIBUTION SYSTEMS (Interior fuel storage, piping, venting, supports, leaks) Maintenance Issues | |
The propane tank inlet line runs into the ground, toward the house, but is exposed at the surface. Care should be taken when working around or near this area, to prevent any damage to the propane gas line.
|
| 8.5 | MAIN FUEL SHUT OFF (Describe Location) Inspected |
| The main fuel shut off is at propane tank outside. |
| Foundation: Masonry block Poured concrete | Method used to observe Crawlspace: Crawled | Floor Structure: 2 X 10 Wood joists Wood beams |
| Wall Structure: Wood 2 X 4 Wood | Ceiling Structure: 2X4 2X8 | Roof Structure: 2 X 6 Rafters |
| Roof-Type: Gable | Method used to observe attic: Walked | Attic info: Attic access Storage Light in attic |
| 9.0 | FOUNDATIONS, BASEMENTS AND CRAWLSPACES (Report signs of abnormal or harmful water penetration into the building or signs of abnormal or harmful condensation on building components.) Repair or Replace | |||
The Foundation wall at the left side (facing front) and right corner (facing rear) has exposed exterior insulation. The insulation should not be exposed, to prevent damage & deterioration. The foundation grading in this area should be improved.
|
| 9.1 | WALLS (Structural) Repair or Replace | |
The sheetrock on the wall has a hairline, settlement crack at the Dining Room main entryway. This damage is most likely cosmetic, caused by minor settling of the home. A qualified structural engineer should inspect and repair as needed.
|
| 9.2 | FLOORS (Structural) Inspected |
| 9.3 | CEILINGS (structural) Inspected |
| 9.4 | ROOF STRUCTURE AND ATTIC Inspected |
| Attic Insulation: Batt Fiberglass R-19 | Ventilation: Gable vents Soffit Vents Thermostatically controlled fan | Exhaust Fans: Fan only |
| Dryer Power Source: 220 Electric | Dryer Vent: Flexible Metal | Floor System Insulation: Batts Fiberglass R-19 |
| 10.0 | INSULATION IN ATTIC Inspected |
| 10.1 | INSULATION UNDER FLOOR SYSTEM Repair or Replace | ||
(1) The insulation is loose/fallen in the crawlspace under the living room. Heat loss can occur more on this home than one that is properly insulated. A qualified person should repair or replace as needed.
| |||
(2) The insulation is loose/fallen in the crawlspace under the living room. Insulation that has fallen to the ground or has become damp from the ground or from condensation usually needs to be replaced with new insulation. A qualified person should repair or replace as needed.
|
| 10.2 | VAPOR RETARDERS (ON GROUND IN CRAWLSPACE OR BASEMENT) Inspected |
| 10.3 | VENTILATION OF ATTIC AND FOUNDATION AREAS Inspected |
| 10.4 | VENTING SYSTEMS (Kitchens, baths and laundry) Repair or Replace | |
The dryer vent piping is no longer used at this location. Any un-used vents should be properly terminated and blocked off, to prevent moisture or pest entry into the house. I recommend repair as needed.
|
| 10.5 | VENTILATION FANS AND THERMOSTATIC CONTROLS (ATTIC) Maintenance Issues | ||
Thermostatically controlled vent fan in the attic is functioning. Location of thermostat control is noted on report detail photograph, for reference. This is for your information. Adjustments are possible, and the homeowner should become familiar with the method of setting.
|